150kw 187.5kva cummins LPG generator set
1. 150kw 187.5kva cummins LPG generator set overall Technical Specifications:
Genset Model | 150GT-CL |
Rated Power | 150KW / 187.5KVA |
Rated Speed/ Rated Frequency | 1500 rpm /50Hz |
Rated Voltage | 400/230V |
Power Factor | 0.8 |
Phase/Wire | 3Phase/4Wire |
Rated current (A) | 270 |
Gas Type | LPG |
Overall Size (mm) | 3250x1160x1900 |
Weight (kg) | 3550 |
Engine Model | Cummins NTA855 |
Air intake way | Turbo intercooled |
Cooling way | Closed cooling cycle |
Cylinder | 6 |
Displacement (L) | 14 |
Bore×Stroke (mm) | 140x 152 |
Max. standby power @50Hz | 165kw/206.25kva |
Alternator Model | STAMFORD UCI274H |
Rated Power | 160kw / 200kva |
Excitation way | Brushless and self exciting |
Voltage control | AVR |
Insulation class | H |
Protection | IP23 |
Remarks:
1. Fuel requirements: Gas low heat value ≥ 48 MJ/Nm3, sulfur content≤200PPM, impurities size≤5μm, impurities content≤50mg/Nm³, water content≤40 g/Nm3; |
2.Optional parts for 150kw 187.5kva cummins LPG generator set
1) Soundproof canopy
2) Parallel cabinet
3) Synchronization cabinet
4) ATS
5) Inlet gas pressure adjusting valve
6) Gas water separator
7) Extra spare parts
3.Warranty policy for 150kw 187.5kva cummins LPG generator set
1). Since genset reached the agreed destination, its main parts will be guaranteed within 12 months or 1000 hours ( subject to the earlier mature term ).
2). We take charge of all troubles caused by genset’s fault and repair according to the regulation stipulated by original plants.
3). Factors not accordance with the regulation of original plants such as fragile parts, daily consumed components, wrong operating, lack of maintenance are not include in the quality guarantee .
4. Declaration for 150kw 187.5kva cummins LPG generator set
The 150kw 187.5kva cummins LPG generator set designed according to environment condition set by ISO 3046: atmospheric pressure 100kpa, sea level height 110m , inlet gas temperature 25℃, relative humidity 30% and reference gross heat value of LPG at minimum 48MJ/NM3. While using places which don’t meet these conditions, generator rated power and outlet gas temperature parameters will be different more or less.
Feature parameters and technical data provided above was calculated through program with massive LPG experiments and actual use data based on environment condition and LPG heat value and content mentioned above.
All generator parameters of 150GF-CL 150kw 187.5kva cummins LPG generator set such as output power, heat consumption were rated value under basic load (100% load). Detailed analysis report of 150kw 187.5kva cummins LPG generator set 150GF-CL in different conditions will be provided by our engineer according to user’s actual environments and gas composition conditions if needed. Other party are not allowed to use our technical parameters for research and business purpose without our permission. We reserved the rights of changing our design without notify customer or the third party.