120kw 150kva cummins LPG generator set

Continuous running 120kw 150kva cummins LPG generator set from China factory, powered by propane, suitable for prime power application, with reliable quality, suitable for north America.

SKU: 120GF-CL Category:
General Details

1. 120kw 150kva cummins LPG generator set overall Technical Specifications:

Genset Model 120GT-CL
Rated Power 120KW / 150KVA
Rated Speed/ Rated Frequency 1500 rpm /50Hz
Rated Voltage 400/230V
Power Factor 0.8
Phase/Wire 3Phase/4Wire
Rated current (A) 216
Gas Type LPG
Overall Size (mm) 2400x1100x1600
Weight (kg) 1950
Engine Model Cummins 6CTAA8.3
Air intake way Turbo intercooled
Cooling way Closed cooling cycle
Cylinder 6
Displacement (L) 8.3
Bore×Stroke (mm) 114×135
Max. standby power @50Hz 132kw/165kva
Alternator Model STAMFORD UCI274F
Rated Power 128kw  / 160kva
Excitation way Brushless and self exciting
Voltage control AVR
Insulation class H
Protection IP23
Remarks:

1.  Fuel requirements: Gas low heat value ≥ 48 MJ/Nm3, sulfur content≤200PPM, impurities size≤5μm, impurities content≤50mg/Nm³, water content≤40 g/Nm3;
2.  Manufacturing standards:ISO8528-5,GB/T2820.5-2009,GB/T22343-2008;
3.  Every gas genset have been pass the test under the load of 0%,25%,50%,75%,100% and the response ability of static, dynamic test, all the protection device and control system are pass strict inspection before they leave factory.

2.Optional parts for 120kw 150kva cummins LPG generator set

1) Soundproof canopy
2) Parallel cabinet
3) Synchronization cabinet
4) ATS
5) Inlet gas pressure adjusting valve
6) Gas water separator
7) Extra spare parts

3.Warranty policy of 120kw 150kva cummins LPG generator set

1). Since genset reached the agreed destination, its main parts will be guaranteed within 12 months or 1000 hours ( subject to the earlier mature term ).
2). We take charge of all troubles caused by genset’s fault and repair according to the regulation stipulated by original plants.
3). Factors not accordance with the regulation of original plants such as fragile parts, daily consumed components, wrong operating, lack of maintenance are not include in the quality guarantee .

4. Declaration for 120kw 150kva cummins LPG generator set

The 120kw 150kva cummins LPG generator set designed according to environment condition set by  ISO 3046: atmospheric pressure 100kpa, sea level height 110m , inlet gas temperature 25℃, relative humidity 30% and reference gross heat value of LPG at minimum 48MJ/NM3. While using places which don’t meet these conditions, generator rated power and outlet gas temperature parameters will be different more or less.

Feature parameters and technical data provided above was calculated through program with massive LPG experiments and actual use data based on environment condition and LPG heat value and content mentioned above.

All generator parameters of 120GF-CL 120kw 150kva cummins LPG generator set such as output power, heat consumption were rated value under basic load (100% load). Detailed analysis report of 120kw 150kva cummins LPG generator set 120GF-CL in different conditions will be provided by our engineer according to user’s actual environments and gas composition conditions if needed. Other party are not allowed to use our technical parameters for research and business purpose without our permission. We reserved the rights of changing our design without notify customer or the third party.

 

Inquire this product

    Product Video